• Make sure the wiring complies with all local codes and ordinances.
• Check to make sure that line voltage wiring is properly connected. Refer to the control label and the appliance wiring diagram for color codes.
• Note that wire colors may vary according to the control manufacturer.

For the R7184A control:
• The black lead (L1) from the R7184A control will connect to the limit of the appliance.
• The white lead (L2) from the R7184A control will connect all neutrals (L2) from the oil burner motor, igniter or ignition transformer and optional valve.
• The blue lead from the R7184A will connect to the solid state igniter or ignition transformer.
• The orange lead from the R7184A will connect to the motor.
• The cad cell connections are spade terminals on the bottom of the R7184A.
• This is the basic wiring for all the R7184 controls. As features are added so is additional wiring, as we will discuss in the next slides.